Home » ACCESS CONTROL

ACCESS CONTROL

ACCESS CONTROL
Checkmate Nv Intelligent Access Controller

Checkmate NV Checkmate Ny is a networkable, intelligent, industry standard Access Control Panel. Designed for use in Building Management System (BMS) applications, Checkmate Ny provides a cost effective solution for Time & Attendance, Access Control & Supervisory Control for Fire & Security Panels. Each Checkmate Ny can monitor & control upto 4 Reader which may be configured to control 4 doors Entry with Reader (Exit with Push Switch) or 2 Doors Entry and Exit Reader or any mixed configuration. The Reader & Lock are connected to the Checkmate Nv in star connection It may be slided on DIN Rail.
Checkmate Nv provides a user configurable intelligent Engine for taking care of any organization’s access control needs and is configured using Web or client based Application software. All the Access Control decisions are taken by the controller making it truly a standalone system independent of PC. Multiple Checkmate Nv’s can be networked on on a Ethernet Network or WiFi (with suitable hardware) for larger applications.
>CARD READER TECHNOLOGY:-
Finger Print Reader
Finger Print Reader works on Biometric Technology. Upto 2 fingers can be enrolled. The Finger Print Reader integrated with Optional Card Reader is used as front end device at the door. Upon Finger Print match, the ID code is transmitted to Checkmate Nv For validation.

Contact less Smart Card Reader:
Contact less Smart card Reader works on 13.56 MHz RF based on MIFARE / iClass Technology.It is useful where Multi-application card is envisaged. MicroSMART/R10 Reader (from HID) complaint to ISO 14443 Protocol, can be used.

Proximity Card Reader(RF ID) :
Proximity Reader is based on 125 KHz RF technology and reads the Proximity cards on show within read range .The Entry level MicroPROX/Prox Point(from HID) reader has a read range of 3″.

Cards:-
Proximity cards/Smart cards compatible to respective readers need to be used. The size of the Card is as per ISO Standard i.e. 85 X 54 mm.


>HARDWARE FEATURES:-
4 Reader Interface
Panel supports 4 Weigand Reader interface. The Reader type supported is Proximity, Smart Card or Finger Print reader. Readers can individually be upto 100 m cable distance from the Controller.
4 Relay Output for Lock Operation
The relay outputs are available for Lock Release, & are tagged to one or more Reader for door operation as per requirement. 12V wetted contact can be provided from the built-in Power Supply for Lock operation.
4 Exit Push Switch Input
There is a provision for 4 Exit Push Switches & is paired with the lock,it is going to release. The switch is normal Push Button offering momentary contact. The lock is operated upon usage for Lock On-Time.
4 Door Open Sensor Input
For monitoring the status of the Door (i.e. Open or Close), Door Open Sensor input is used. The Door open sensor input is paired with a lock. It is useful for Turnstile operation for locking it upon rotation feedback.
4 General Purpose Input (GPI)
There is a provision for Potential free contact inputs, which can be input from Fire/Intruder Alarm panel & can be programmed to make the Controller Fail Safe /Fail Secure, in emergency situation.
4 General Purpose Output (GPO)
The General purpose outputs are available for Alarm annunciation in case of emergencies. The GPO’s are paired with GPI’s.Potential free contact may be optionally provided.
Built-in Lock Power Supply
A Bulk 12V Power Supply is centrally connected to the controller to power the locks thereby removing the necessity for power supplies near lock. Optionally, UPS with battery may be provided.
CABLING:-
Cabling 6 core multi strand (each core 14/36) shielded cable for Reader is used. One Pair each of electrical multi strand cable(each core 1.5 sq mm) is used for Lock operation, Door Open Sensor and Exit Switch. These cables run from each Door to Controller. Cable length should be within 100 m.

>ACCESS CONTROL FEATURES:-

ACCESS GROUP : 4 Access Groups may be defined. Each Access Group are associated with one or more locks. One or more Readers/Exit switches are linked to a lock in an Access Group.
ATTENDANCE GROUP. : Attendance Group is used for recording Employee  Attendance and accepts all cards at all time. These data are later used for Attendance Report generation.
GROUP ANTI-PASS BACK : Enable/Disable for each Access Group. Hard Anti-pass back : No exit w/o valid Entry, violation alarm. Soft Anti-pass back : Exit w/o Valid Entry with violation alarm.
TIME ZONE : 8 user definable Time zones per Access Group. The Time Zones could be Enabled/Disabled for Holiday/ Weekly off. “ALLOW ALL” Time Zone is possible for rush hours.
CARD HOLDER DATABASE : Each Access Group has its own set of Card Holders linked to one or more Time Zones for the Group. Card holder can be member of Multiple Access Groups. Upto 30,000 IDs over all the Access Groups.
VISITOR DATABASE: A visitor based on entry from the Central Computer would have access defined based on the Access Group. The Access rights can be withdrawn upon visitor leaving. Upto 2000 visitor ID database may be defined.
 HOLIDAY DATABASE TABLE : 30 Holiday Dates & a Weekly off Day can be defined for barring Access. 3000 Card holders can provide access irrespective of Holidays based on their default Access Groups & Time Zones.
HOLIDAY MASTER CARD : For Card holders not included in Holiday Database Table, requiring entry on holiday/weekly off in their Time Zone, Master Card needs to be shown before the Card Holders card. Upto 5 Holiday master cards per Access Group may be defined.
DOOR OPEN TO LONG (DOTL) : If the Door open sensor input is ON for a period longer than the Lock on – time, Alarm is raised & recorded. This may be used for on-line monitoring of doors on Central Monitoring Computer.
LOCK ON-TIME : Lock on-time for door opening after Card Show is User Settable. The Lock shuts after this time. This can be used with Door open Sensor for exception monitoring.
EMERGENCY OPERATION : All Doors are opened based on Fire Alarm /closed in case of Burglar Alarm Panel Input. Resetting of Alarms results in normal operation.All alarms are logged for analysis.
ACCESS RIGHTS EMERGENCY OPERATION : Card Holders can be temporarily Enabled/disabled from the Card Holder Table in the Controller. This feature is useful in case of ID card loss.
EMERGENCY LOCK OPEN : Central Computer can open a lock remotely with authorization. All such events are logged.

Checkmate NV 8 Single Door Access & Attendance System

Checkmate Nvs is a 8 Reader Control Panel In the same foot print using Double Decker concept. Checkmate Ny may be upgraded on field to Checkmate Nys.
Checkmate XR is specially designed for Biometric Reader nodes. It may be connected to upto 8 Nos. of MicroTIP(Fortuna’s Biometric) Reader, using CAT 5 cable in Star connection. The Finger Templates may be uploaded/ downloaded thru this cable. Hence there is no need of a separate LAN cable/IP Address for managing the Finger template, which saves a lot of wiring & IT cost.
ORDERRING INFORMATION:-
Checkmate Nv
: Access Controller with 4 Weigand Reader I/F.
Checkmate Nv8: Access Controller with 8 Weigand Reader 1/F.
Checkmate xR: Access Controller with 8 Bio-metric Reader 1/F.
UPS with Battery : UPS with battery for 4 hours back-up time.
MiniProx/Prox Point Plus : HID Proximity Card Reader MicroPROX: Proximity Card Reader with Read Range upto 3.
MicroSMART : Contact less Smart Card Reader (Read Range up to 3).
Micro TIP : Integrated Finger Print and Contact less HID card Reader.
COMPRO XP : Configuration, Data Capture and Reporting Software.
MIS Time Pro LITE : Time Office Management Software.
MIS Time Pro Enterprise : Time Office Management Software for Factory.
justHRMS : Web based HR & Attendance Management Software.
ID Card : (a) Proximity Card (b) Contact less Smart Card (1K/4K).
Door Lock : (a)Strike (b)EM Lock (c)Turnstile (d)Drop bolt (e)Boom.
Cable : (a)Reader Cable (b) Communication cable (c) Lock Cable.
Accessories : (a)Exit Switch (b) Door Sensor.

TECHNICAL INFORMATION:- 

CPU High Performance 16 bit Microcontroller
Memory 12500 Transaction Data Storage with ID #, Date, Time and Access Information. Separate table for Event Storage.
Battery Back-up Retention of Clock & Data under power-off
Communication RS232C or RS485(Isolated) (Ethernet or Modem Connectivity using additional hardware)
Data Upload Speed 1000 Records/Minute(9600BPS)
CPU Power Wide Range SMPS(170V to 260V@50Hz +/-5Hz,5W)
Lock Power Built-in 12V/3 Amp Power Supply for Locks
UPS with Battery Optionally available with 4 hours back-up time
Card Reader Interface 4 Reader 26/34 bit Weigand Interface
Relay Output 4 Potential Free/12V Wet Contact O/P for Locks
Exit Switch 4 Exit Switch Input Interface
Lock Feedback 4 Door Open Sensor Interface for Lock Feedback
General Purpose Input/Output 4 GPI and 4 GPO(TTL Level)
Dimension 350mm(H) X 375mm(W) X 90(D) mm
Enclosure Dust Resistant,Corrosion Free MS Casing
Colour Powder Coated Light Gray
Operating Temperature 0-55 Degree Centigrade